Analysis ranges of 0-2000ppm up to 0-100% vol/vol.
Simply introduce your sample gas flow into the inlet of the Model 908 portable CO2 analyzer, and see results on the LCD within 15-20 seconds. The inlet accepts a flow rate of 50cc/min to 1000 cc/min. If you don’t have a source of flow or positive pressure, the analyzer can be equipped with an internal pump to draw in sample gas for analysis.
HIGHLY PORTABLE
The Model 908 portable analyzer weighs about 2 lbs and is easily carried via shoulder strap. Battery operation is included and provides approximately 10-12 hours of run time.
EASE OF USE
Simply connect the included sample tubing to your inlet connector or port. If you have a source of flow, you will achieve a reading in about 15-20 seconds. If you do not have a source of flow, the analyzer can be equipped with an internal sampling pump to draw sample into the analyzer.
CO2 SENSOR – BASICS
The sensor design has a low internal volume and requires only a low sample flow of about 5 to 1000 cc/min. Our market leading CO2 sensor uses the latest in dual-wavelength NDIR measurement principles, reducing drift and allowing for a single point calibration. While the sample introduced should be clean and dry (non-condensing), should moisture enter the analyzer, the Model 908 is equipped with an internal moisture trap filter. This provides a last barrier of protection, and is user-replaceable (we provide spares).
CO2 SENSOR – DETAILS
The instrument uses a solid-state infrared sensor which has no moving parts, a compact optical cell, and microprocessor-based calibration factors using a 6th order polynomial equation to linearize the full range measurement up to 100%. Infrared CO2 measurements are inherently non-linear, especially over a high range of concentrations. The math algorithm used in the 906 yields more accurate measurements over a much wider range of concentrations than other methods.
DATA COLLECTION OPTIONS
The Model 908 can be equipped with a data logger which fits in the carrying case. This data logger will continuously collect the readings from the analyzer. Use the included software to analyze the data, conduct statistical analysis (such as analyzing averages and standard deviations).
ABOUT THE BATTERY
The 908 CO2 analyzer is equipped with an advance 10 cell NiMH battery pack. The charger module plugs into any international 100-240V outlet, for charging or continuous operation.
ABOUT THE WARRANTY
The portable CO2 analyzer is backed it up with a two year warranty, twice the industry standard. The advanced design allows an output requiring less frequent calibration. It provides a stable, drift-free linearized voltage or current output that is much less susceptible to external electro-magnetic interference than conventional analog electronics.
Specification :
- Range – 0.0 to 100% Carbon Dioxide (Other Ranges: 0 to 2000/5000ppm, 0-1%, 0 to 2.5%, 0 to 10%, 0 to 20%, 0-30%, 0-50%)
- Resolution – 0.1% CO2 for 0 to 30, 0-50, and 0 to 100% ranges (0.01% CO for 0 to 2.5%, 0 to 10%, or 0 to 20% ranges) (0.001% CO2 for 0 to 1%) (1ppm for 0-2000ppm)
- Accuracy – +/-1% of reading, or 0.2% CO2 for 0-100% range (+/- 3% of reading, or 75ppm for 0-2.5% and lower ranges)
- Drift – less than 0.02% per month
- Sensor- Infrared (NDIR); non-depleting with no moving parts
- Sensor Body – Anodized aluminum
- Calibration – Single Point Calibration – With standard calibration gas (available from Quantek if needed); SPAN adjustment on rear panel
- Calibration Frequency – Within two years of original manufacture; each year thereafter
- Power Supply – Internationally compatible charger or power supply, 100/240V (50/60Hz) to 12V
- Sample Pump – Optional; internal, with on-off switch on front panel, draws about 5 cc/sec
- Battery Operation – Included, with internal rechargeable 12 Vdc NiMH battery pack
- Size – 8 in. x 2 in. x 7 in. (203 mm x 51 mm x 178 mm)
- Weight – 2 lbs. (0.9 kg)
- Warranty – Two Years, parts and labor
- Standards – CE, RoHS
- Consumables – Internal, user-replaceable moisture and particulate filter; external 4in. moisture removal cartidges
- Origin of Goods – Our goods are manufactured in the U.S.A.
Application :
- Bioreactors
- Gas Blending Systems
- Fruit Storage Areas
- Fermentation
- Algae Experiments
- Welding Gases
- Controlled Atmosphere Rooms
- Carbon Capture and Storage
- Incubation Experiments
- Cell Culture analysis
- Greenhouse CO2 Research
- Biofuel Experiments
- CO2 Mitigation Research
- ….. and Many More
Included :
- Internationally compatible (100-240V) power supply / charger
- A – double orange connector (1/16 ID tubing) – useful if you choose to inject sample gas into the inlet of the analyzer using the supplied 60 cc syringe.
- B – Two particulate filters – These leur-fit filters can be attached to the inlet fitting of the analyzer to provide extra protection from particulates.
- C – T style connector – This fitting is useful as a flow limiter – by passing your sample gas through this fitting, and leaving one of the T stems open, you can reduce the flow reaching the analyzer.
- D – Inlet fitting (accepts 1/4in ID tubing) – This is a replacement spare for the inlet fitting in the event that your original fitting is damaged or the threads stripped.
- E – Adjusting screwdriver for potentiometers – This screwdriver fits the potentiometers on the back of the analyzer.
- F – Rubber Washers – These are replacement rubber washers. One is already installed behind the inlet fitting to provide a leaktight seal.
- G – 60 cc syringe for sample injection – Useful for syringe injection. Note, however that this method may require at least 120 cc of gas to get a proper reading.
- H – 1/16 ID tubing – This tubing can be attached to one of the orange hubbed needles, and affixed to the inlet fitting.
- I – Internal inline moisture trap filter (PTFE .45 micron) – This filter is a replacement for the inside particulate and moisture filter in the analyzer. Should you accidentally allow moisture into your gas flow, then find the readings not to change as expected, then you may need to replace this filter inside the analyzer by removing the top cover. This is a four layer filter which will completely block gas flow upon saturation.
Optional :
- Internal Pump – A mini diaphram pump installed inside the analyzer, and draws approximately 5 cc per second. Great for situations where there is no source of flow. Expected -pump lifetime is 8-10 years. The pump can be used in two modes – one mode is clicked “on” and leaves the pump running until unclicked. Pressing the switch lightly enables operation according to the user adjustable potentiometer timer.
- Data Logger – Our data logger includes everything you need for collecting analysis data from our benchtop analyzers. The data logger is used to collect measurements for offloading to a PC or Mac
- Fine .01% Resolution – An extra digit of resolution can be provided for applications where accuracy is of the utmost importance. Please note that for 0-20% CO2 analysis range, we can provide this at no additional charge.
- Tubing / Fittings – if you need a specific tubing for an access port, or a different type of probe, please inquire.

Category: Uncategorized
It¦s really a cool and useful piece of info. I¦m satisfied that you simply shared this useful info with us. Please stay us up to date like this. Thanks for sharing.
https://www.zoritolerimol.com
you’ve gotten a fantastic weblog right here! would you like to make some invite posts on my weblog?
https://www.droversointeru.com
I got this web site from my friend who informed me concerning this website and now this time I am visiting this web site and reading very informative posts here. Продажа детских колясок
Its like you read my mind! You seem to know so much about this, like you wrote the book in it or something. I think that you could do with some pics to drive the message home a bit, but other than that, this is fantastic blog. A great read. I’ll definitely be back. Детские коляски
What’s up mates, how is all, and what you desire to say about this post, in my view its in fact awesome in favor of me. Детские коляски